Product specifications

CDM-Qx/QxL Multi-Channel Satellite Modem with DoubleTalk™ Carrier-in-Carrier® Revision 7
Front Panel Operation MN/CDMQX.IOM
5–18
Press either ENTER or CLEAR to return to the previous menu (with Manual selected).
With Framed Mode properly configured, selecting AUPC results in display of the following
submenu:
Target-Eb/No Max-Range Alarm
DemodUnlock ( ,ENT)
Select Target EbNo, Max-Range, Alarm, or DemodUnlock using the W X arrow keys,
then press
ENTER.
CONFIG: Tx Æ Pwr Æ AUPC Æ Target-Eb/No
Remote Demod - Target Eb/No
Min Eb/No:9.9dB ( , ,ENT)
Edit the Transmit AUPC Target Eb/No value by first using the W X arrow keys to
select the digit to be edited; the value of the digit is then changed using the
ST arrow
keys. The default value is 3.0 dB; the upper limit is 9.9 dB. Press
ENTER when done.
CONFIG: Tx Æ Pwr Æ AUPC Æ Max-Range
Maximum-permitted Power
increase: 01dB ( ,ENT)
Edit the Transmit AUPC Maximum Permitted Power Increase value (when in AUPC
mode) by first using the
W X arrow keys to select the digit to be edited; the value of the
digit is then changed using the
ST arrow keys. The default value is 1 dB; the upper limit
is 9 dB. Press
ENTER when done.
CONFIG: Tx Æ Pwr Æ AUPC Æ Alarm
Action when max Tx Power
reached: None TxAlarm ( ,ENT)
To set the action that will occur if the AUPC causes the maximum output power level to be
reached, select None or TxAlarm using the
W X arrow keys, then press ENTER.
CONFIG: Tx Æ Pwr Æ AUPC Æ DemodUnlock
Action when Remote Demod
unlocks: Nom-Pwr Max-Pwr
To select the action that will occur if the remote demod is unlocked, using the W X arrow
keys, select Nom-Pwr (Nomimal Power, where the output level will revert to the nominal
power level that was set under Manual) or Max-Pwr (Maximum Power, where the output
level will change to the maximum permitted). Press