Product specifications

CDM-Qx/QxL Multi-Channel Satellite Modem with DoubleTalk™ Carrier-in-Carrier® Revision 7
Front Panel Operation MN/CDMQX.IOM
5–52
5.6.2.2 TEST: BIST Æ BERT-Mon
BERT Monitor: Errs=0000253
BER=8.5E-07
If BERT monitor is turned ON, results are being displayed in bit errors and average BER. If it
displays BER=SyncLoss that means there was a loss of pattern synchronization. If it displays
BER=No Sync, that means pattern synchronization is not achieved. When the BERT monitor is
sync, the BER displays a value (e.g. BER=8.5E-07).
5.6.2.3 TEST: BIST Æ BERT-Control
BERT Control: 10E-3Err=OFF
Restart=NO SyncThres=>256
Note the following:
The 10E-3Err control resides at the Tx. This generates an average BER=1.0E-03 once
monitored at the Rx side.
The Restart control is to reset the BERT monitor (Rx side) for a fresh start of BER
measurement.
The SyncThres control is the synchronization loss threshold as defined:
a. >256 = 256 bit errors counted in less than 1000 bits o data
b. low = 100 bit errors in less than 1000 bits of data
c. med = 250 bit errors in less than 1000 bits of data
d. high = 20,000 bit errors in less than 100,000 bits of data
5.6.3 TEST: Spec-Analyzer
Spectrum Analyzer:
Mode Config ( ,ENT)
Select Mode or Config using the arrow keys, then press ENTER.
TEST: Spec-Analyzer Æ Mode
Spectrum Analyzer Mode:
Off On ( ,ENT)
To control the engine of the spectrum analyzer, select Off or On using the arrow keys,
then press
ENTER. When the Spectrum Analyzer Mode is On, the user can view the spectrum
via Comtech EF Data’s Windows-based application software or the CDM-Qx/QxL embedded
Web browser.
TEST: Spec-Analyzer Æ Config
Config Spectrum Analyzer:
CenterFreq Span ( ,ENT)
Select CenterFreq or Span using the arrow keys, then press ENTER.