Product specifications

CDM-Qx/QxL Multi-Channel Satellite Modem with DoubleTalk™ Carrier-in-Carrier® Revision 7
Front Panel Operation MN/CDMQX.IOM
5–38
IMPORTANT
5.4.8.3 CONFIG: Mask Æ Reference
Reference Alarm:
Active Masked ( ENT)
Select Active or Masked using the arrow keys, then press ENTER. If Active is selected, then
a unit fault will be generated whenever:
an External Reference is selected;
there is no signal activity at the external reference port.
If Masked is selected, no alarm will be generated.
5.4.8.4 CONFIG: Mask Æ BUC (CDM-QxL only)
BUC Alarm:
Active Masked ( ENT)
Select Active or Masked using the arrow keys, then press ENTER. If Masked is selected, no
alarm will be generated.
5.4.8.5 CONFIG: Mask Æ BUC (CDM-QxL only)
LNB Alarm:
Active Masked ( ENT)
Select Active or Masked using the arrow keys, then press ENTER. If Masked is selected, no
alarm will be generated.
5.4.9 CONFIG: ODU
These menus are operable only for CDM-QxL L-Band units.
ODU (Outdoor Unit):
BUC LNB ( ,ENT)
The ODU (Outdoor Unit) menu permits the user to choose between controlling and monitoring
either a BUC (Block Upconverter) or an LNB (Low-noise Block downconverter).
Select BUC or LNB using the arrow keys, then press
ENTER.
5.4.9.1 CONFIG: ODU Æ BUC
BUC: M&C-FSK DC-Pwr 10MHz
Alarm Delay LO Mix ( ,ENT)
Select M&C-FSK, DC-Pwr, 10MHz, Alarm, Delay, LO or Mix using the arrow keys,
then press
ENTER.