Product specifications

CDM-840 Remote Router Revision 0
Ethernet Management MN-CDM840
5–28
5.4.4.4.7 Configuration | BUC (Block Up Converter)
Figure 5-17. Configuration | BUC page
The ‘Configuration | BUC’ page (Figure 5-17) is used to configure Block Up Converter
parameters, and display the BUC status for L-Band o
peration.
BUC
The acceptable/valid operating range for each item in this section is provided in brackets.
BUC LO Freq (MHz) [3000 – 65000] – Enter the BUC’s Local Oscillator frequency in MHz.
BUC Power Supply – Use the drop-down menu to select the BUC Power Supply as either Off
or On.
BUC 10 MHz Reference Enable – Use the drop-down menu to select the BUC 10 MHz
Reference Enable as either Off or On.
BUC Low Current Limit (mA) [0 4000] – Enter the BUC’s low current alarm limit in 100mA
increments.
BUC High Current Limit (mA) [0 4000] – Enter the BUC’s high current alarm limit in 100
mA increments.
Once the desired configuration settings have been made in this section, click [Submit BUC
Control] as needed to save these changes.
Actual BUC Voltage (V) and Actual BUC Current (mA) – BUC power supply voltage and
current information is continuously monitored and is provided here on a read-only basis. Click
[Refresh] to update these readings.