Product specifications
ErrataAforMN/CDM710.IOMRev11 Update'FLT'SerialRemoteControlQuery
ER-CDM710-EA11 THIS DOCUMENT IS NOT SUBJECT TO REVISION/UPDATE! PLM CO C-0025029 Page 4 of 4
Parameter
Type
Command
(Instruction
Code and
Qualifier)
Arguments for
Command or
Response to
Query
Description of Arguments
Response to
Command
Query
(Instruction
Code and
Qualifier)
Response to Query
Faults and
Status (cont.)
C= Reserved
D= ASI Port Transmit Data Loss (Interface 1)
E= Reserved
F= ASI Frame Not Synchronized (Interface 1)
G= Reserved
H= HSSI TX Clock Failure (Interface 1)
I= Reserved
J= GBEI Card Datarate > + 200 PPM
K= GBEI Card Datarate < - 200 PPM
L= GBEI No PHY Link
M= Encoder FIFO Empty
N= Encoder FIFO Full
O= ASI Tx Input Datarate Offset > +110PPM (Interface 1)
P= Reserved
Q= ASI Tx Input Datarate Offset < -110PPM (Interface 1)
R= Reserved
S= SERDES Parity Errors
c=Rx Traffic Status
0=No faults
d=New Faults
0=No new faults
1=New faults since last check
e=Configuration change
0=Modem configuration has not been changed
1= Modem configuration has been changed