Product specifications

CDM-710 Broadcast Satellite Modem Revision 10
Front Panel Operation MN/CDM710.IOM
5.3.6 (SELECT:) Util (Utility)
UTIL: RT-Clk Ref ID
Display Firmware FAST
Select RT-Clk, Ref, ID, Display, Firmware, or FAST using the arrow keys. The User
should then press
ENTER.
5.3.6.1 (SELECT:) UTIL: Æ RT-Clk
Edit Real-Time Clock:
10:23:51 23/05/06 ( E)
Edit the time and date settings of the real-time clock by selecting the digit to be changed, using
the arrow keys. The value of the digit is then changed using the ST arrow keys. The User
should then press
ENTER.
Note: In accordance with international convention, the date is shown in DAY/MONTH/YEAR
format.
5.3.6.2 (SELECT:) UTIL: Æ Ref
Internal 10 MHz Ref Freq
Fine Adjust:+1911
This menu provides a fine adjustment for the internal 10 MHz reference.
For ‘Tx Only’ or ‘Full Duplex’ units, use the Tx IF Carrier to check the reference frequency by
first placing the unit in the
Tx-CW mode from the Test menu.
In ‘Rx Only’ units, 10 MHz is available at J6-8 or J6-9 only while within the Utility: Ref menu.
5–54