Product specifications
CDM-710 Broadcast Satellite Modem Revision 10
Front Panel Operation MN/CDM710.IOM
5.3.1.7 (CONFIG:) Ref
Frequency Reference
External 10 MHz (cbE)
External 10 MHz
The unit phase locks to an external input at the BNC connector
labeled EXT REF. Other selections are available for External 1, 2,
5, 10, or 20 MHz input.
Note: Internal selection is available at 10 MHz.
5.3.1.8 (CONFIG:) Aux
Redundancy
Ena/Dis Force (1:1) ( E)
Select Ena/Dis or Force (1:1) using the ◄ ► arrow keys. The User should then press
ENTER.
If (Aux) Redundancy Æ Ena/Dis is selected:
Redundancy Mode:
Enable Disable ( E)
The solid cursor indicates the current configuration choice. Select Enable to set up the unit for
operation with the 1:1 IF switch. Internally, an auxiliary relay sets the alarms connector for the
1:1 operation mode.
Note: Disable is selectable only when the unit is in Local mode. When the unit is in Remote
mode and the User attempts to select Disable using the ◄ ► arrow keys, the following message
is displayed:
THIS UNIT IS CURRENTLY
IN REMOTE MODE!!
Note: When redundancy is selected, J5 becomes the active port – J4 is not available for 1:1
operation. Either J4 or J5 is available for 1:N operation.
If (Aux) Redundancy Æ Force (1:1) is selected:
Press ENT To Force Modem
To Standby (1:1 Only)