Product specifications
CDM-710 Broadcast Satellite Modem Revision 10
Front Panel Operation MN/CDM710.IOM
Select Dual for redundancy operation with dual IP connections, each transporting an MPEG-2
transport stream, and automatic switching between the two streams is performed.
If Intfc2 Gigabit Ingress: Æ Intfc2 Streams Æ Pri is selected:
Intfc2 Primary Stream
1 2
Select either stream 1 or stream 2 as the primary stream using the
◄ ► arrow keys. The User
should then press
ENTER.
In single mode, this assigns which (of up to two) streams is processed. In redundancy mode, this
identifies which of two streams are initially processed before any redundancy switch takes place.
If Intfc2 Gigabit Ingress: Æ Intfc2 Streams Æ Red is selected:
Intfc2 Redundancy:
Revertive Non-Revertive
Select Revertive or Non-Revertive, using the ◄ ► arrow keys. The User should then press
ENTER.
In Revertive Redundancy mode, either stream can be processed in the event of the failure of the
other stream. In Non-revertive Redundancy mode, a switch from the primary stream to the
secondary stream can occur, but a switch from the secondary stream to the primary stream will
not occur in the event of a failure of the secondary stream. In this latter case, user intervention
is required.
If Intfc2 Gigabit Ingress: Æ Intfc2 Streams Æ Timeout is selected:
Intfc2 Stream Timeout
0500 mS ()
Using the ▲ ▼ arrow keys, assign the period (in 100 mS increments) for a primary connection
failure to be present before switchover to the secondary connection occurs. Note: For use in Dual
stream mode only. The User should then press
ENTER.
(CONFIG:) Intfc2 Gigabit Ethernet: Æ Egress
Intfc2 Gigabit Egress:
Ena/Dis FEC IP
Select Ena/Dis, FEC, or IP using the ◄ ► arrow keys. The User should then press
ENTER.
5–34