Product specifications

CDM-710 Broadcast Satellite Modem Revision 10
Front Panel Operation MN/CDM710.IOM
5–24
Edit the Eb/No alarm point by selecting the digit to be edited, using the arrow keys. The
Eb/No Alarm: Æ Alarm/Fault is selected:
value of the digit is then changed using the
arrow keys. The range of values is from 0.1 to
16.0 dB. The User should then press
ENTER.
If
Eb/No Alarm:
Alarm Fault Mask ( E) 
Select Alarm, Fault, or Masked using the
arrow keys. The available choices define the
(CONFIG:) Rx Æ PLL
Eb/No Alarm as an Alarm, as a Fault, or to completely Mask the alarm. This choice affects
operation in 1:1 redundancy. The User should then press
ENTER.
Carrier PLL Bandwidth:
1x 2x (E)
Select 1x or 2x using the
arrow keys. The User should then press ENTER. This selection is
5.3.1.4 CONFIG: Intfc1 ASI (CDI-40 ASI Interface Only)
sometimes useful when high phase noise is present. 1x is the normal operating mode.
This menu branch shows what is available if Interface 1(the Interface in Slot 1) is populated with
the CDI-40 ASI Interface card. The ASI interface is available in Slot 1 only. The menus and
submenus depicted in this section allows enabling or disabling of the ASI interface, and are
dependent on this installed interface.
Intfc1 ASI:
Tx Rx Config ( E) 
Select Tx, Rx, or Config using the
arrow keys. The User should then press ENTER.
(CONFIG:) Intfc1 ASI: Æ Tx
Intfc1 ASI Tx:
Ena/Dis Frame ( E)
Select Ena/Dis or Frame using the arrow keys. The User should then press
ENTER.