Product specifications
CDM-710 Broadcast Satellite Modem Revision 10
Front Panel Operation MN/CDM710.IOM
If Interface Æ RS232 is selected:
In RS232 Mode the Bus
Address is fixed at 0000
If Interface Æ RS485 is selected, the User will be further prompted:
RS485 Mod Address: 0001
(E)
Edit the RS485 address of the modem by selecting the digit to be edited, using the ◄ ► arrow
keys. The value of the digit is then changed using the ▲ ▼ arrow keys. The valid range of
addresses is from 1 to 9999. The User should then press
ENTER.
If Serial CONFIG: Æ Baudrate is selected:
Local M&C Bus Baud Rate:
9600 Baud ( E )
Edit the Baud rate of the remote control bus, connected locally to the M&C computer. Values of
1200, 2400, 4800, 9600, 19200, 38400, and 57600 baud are possible. The value is changed using
the ◄ ► arrow keys. The User should then press
ENTER.
Note: The Asynchronous character format is FIXED at 8 data bits, No parity, and 1 stop bit (8-N-1).
(CONFIG:) Remote Control Æ Ethernet
Ethernet CONFIG: Gateway
Address MAC SNMP ( E)
Select Gateway, Address, MAC, or SNMP using the ◄ ► arrow keys, then press
ENTER.
If Ethernet CONFIG: Æ Gateway is selected:
Ethernet IP Gateway:
063.168.001.127 ( E )
Edit the Gateway address by selecting the digit to be edited, using the ◄ ► arrow keys. The value
of the digit is then changed using the ▲ ▼ arrow keys. The User should then press
ENTER.
5–9