Product specifications
CDM-710 Broadcast Satellite Modem Revision 10
Front Panel Operation MN/CDM710.IOM
5.3.1.1 (CONFIG:) Remote Control
Remote Control:
Local Serial Ethernet
Select Local, Serial or Ethernet by using the ◄ ► arrow keys, then press
ENTER.
Selection Action
Local
Remote control is disabled. Remote monitoring is still possible.
Serial
RS232, RS485-2W, and RS485-4W menus are accessed.
Ethernet
Additional sub-menus will be displayed.
(CONFIG:) Remote Control Æ Local
IMPORTANT
When Local is selected, remote control is disabled and local control enabled
once ENTER is pressed; the User is returned to the CONFIG: menu. When
Remote is selected, menu operations associated with local control are disabled,
and the User may see the following message when menu or command access
associated with Local control is attempted:
THIS UNIT IS CURRENTLY
IN REMOTE MODE!!
(CONFIG:) Remote Control Æ Serial
Serial CONFIG:
Interface Baudrate (E)
Select Interface or Baudrate using the ◄ ► arrow keys, then press
ENTER.
If Serial CONFIG: Æ Interface is selected:
M&C Bus Interface: RS232
RS485-2W RS485-4W (E)
Select RS232 or RS485-2W (2-wire) or RS485-4W (4-wire) using the ◄ ► arrow keys, then
press
ENTER.
Note: At this point the User will be further prompted to enter the bus address.
5–8