Product specifications

CDM-710 Broadcast Satellite Modem Revision 10
Remote Control MN/CDM710.IOM
A–80
[Interface Block] consists of 130 bytes and contains the configuration of the current enabled interface on the unit. The format of the configuration bytes
depend on the interface type indicated by the 5
th
byte in the MGC query or command.
If ASI interface then format is: abcdx…xxx
a = ASI Bandwidth same as TAB (omit interface slot parameter)
b = ASI Port same as TIP (omit interface slot parameter)
c = ASI Tx Frame Size same as ATF (omit interface slot parameter)
d = ASI Rx Frame Size same as ARF (omit interface slot parameter)
x…xxx = spare bytes
If Gigabit Ethernet interface then format is:
aaa.aaa.aaa.aaabbb.bbb.bbb.bbbccc.ccc.ccc.cccddd.ddd.ddd.dddeefghiiiiijkkk.kkk.kkk.kkklmmmmmnnnnnooppxxx…xxx
aaa.aaa.aaa.aaa = Ingress Multicast Group Address #1 same as GMI (omit interface slot parameter)
bbb.bbb.bbb.bbb = Ingress Multicast Group Address #2 same as GMI (omit interface slot parameter)
ccc.ccc.ccc.ccc = Ingress Multicast Source Address #1 same as GSI (omit interface slot parameter)
ddd.ddd.ddd.ddd = Ingress Multicast Source Address #2 same as GSI (omit interface slot parameter)
ee = Buffer Timeout same as GTO (omit interface slot parameter)
f = Primary Stream same as GSP (omit interface slot parameter)
g = Stream Mode same as GSM (omit interface slot parameter)
h = Ingress FEC Enable same as GFE (omit interface slot parameter)
iiiii = Ingress UDP Port same as GFP (omit interface slot parameter)
j = Buffer Timeout Mode same as GTM (omit interface slot parameter)
kkk.kkk.kkk.kkk = Egress Multicast Group same as GEG (omit interface slot parameter)
l = Egress FEC Enable same as GEF (omit interface slot parameter)
mmmmm = Egress Source Port same as GEP (omit interface slot parameter)
nnnnn = Egress Destination Port same as GEP (omit interface slot parameter)
oo = FEC Matrix Length same as GFM (omit interface slot parameter)
pp = FEC Matrix Depth same as GFM (omit interface slot parameter)
xxx…xxx = spare bytes
If HSSI interface, then format is: abcdeff.fx…xxx
a = Tx Data Inversion same as TDI (omit interface slot parameter)
b = Rx Data Inversion same as RDI (omit interface slot parameter)
c = Tx Clock Inversion same as TCI (omit interface slot parameter)
d = Rx Clock Inversion same as RCI (omit interface slot parameter)
e = Rx Clock Source same as RCK (omit interface slot parameter)
ff.f = Rx Buffer Size same as RBS (omit interface slot parameter)
x…xxx = spare bytes