Product specifications

CDM-710 Broadcast Satellite Modem Revision 10
Remote Control MN/CDM710.IOM
A–72
Parameter
Type
Command
(Instruction
Code and
Qualifier)
Arguments
for Command
or Response
to Query
Description of Arguments
Response
to
Command
Query
(Instruction
Code and
Qualifier)
Response to Query
Gigabit Egress
FEC Enable
GEF= 2 bytes Command or Query.
Gigabit Egress FEC Enable/Disable.
s=Slot (1, 2)
n=Enable / Disable, where
0 = Disabled
1 = Enabled
GEF=
GEF#
GEF?
GEF*
GEF?s GEF=sn
Gigabit Egress
Multicast
Group Address
GEG= 16 bytes Command or Query.
Gigabit Egress Multicast Group Address. The multicast stream
egressing from the gigabit interface will have this ip address as
the source IP address.
s=Slot (1, 2)
iii.iii.iii.iii=IP Address
GEG=
GEG#
GEG?
GEG*
GEG?s GEG=siii.iii.iii.iii
Gigabit Egress
Port Numbers
GEP= 11 bytes Command or Query.
Gigabit Egress Port Numbers
s=Slot (1, 2)
nnnnn = Source Port Number (0 – 65535)
ppppp = Destination Port Number (0 – 65535)
GEP=
GEP#
GEP?
GEP*
GEP?s GEP=snnnnnppppp
Gigabit Egress
FEC Matrix
GFM= 5 bytes Command or Query.
Gigabit Egress FEC Matrix.
s=Slot (1, 2)
ll = Length, two digit number (leading zero) between 1 and 20.
dd = Depth, two digit number (leading zero) between 4 and 20.
**( Length x Depth, must be less than or equal to 100 )
GFM=
GFM #
GFM?
GFM*
GFM?s GFM=slldd
Initialize
Events Pointer
IEP= None Command Only.
Resets internal pointer to allow RNE? queries to start at the
beginning of the stored events log.
IEP=
IEP?
IEP*
IEP#
N/A N/A
Boot Image IMG= 1 byte Command or Query.
Boot image selection, where n is the image number:
1=Image #1
2=Image #2
Example: IMG=1 (Selects Image #1 for booting.)
IMG=
IMG?
IMG*
IMG#
IMG? IMG=n