Product specifications
CDM-710 Broadcast Satellite Modem Revision 10
Remote Control MN/CDM710.IOM
A–64
Parameter
Type
Command
(Instruction
Code and
Qualifier)
Arguments
for Command
or Response
to Query
Description of Arguments
Response
to
Command
Query
(Instruction
Code and
Qualifier)
Response to Query
ASI Rx Frame
Size
ARF= 2 bytes Command or Query.
Indicates whether the ASI Rx Frame Size is 188 or 204 bytes
(ASI card only), in the form: sf
Where:
s = interface slot ( 1 or 2 )
f = frame size
0 = 188 bytes
1 = 204 bytes
Example: ARF=11 ( sets interface slot 1 to 204 byte frame size)
ARF=
ARF?
ARF*
ARF#
ARF?s ARF=sf
ASI Tx Frame
Size
ATF= 2 bytes Command or Query.
Indicates whether the ASI Tx Frame Size is 188 or 204 bytes
(ASI card only), in the form: sf
Where:
s = interface slot ( 1 or 2 )
f = frame size
0 = 188 bytes
1 = 204 bytes
Example: ATF=11 ( sets interface slot 1 to 204 byte frame size)
ATF=
ATF?
ATF*
ATF#
ATF?s ATF=sf
Clear All
Stored Events
CAE= None Command Only.
Forces the software to clear the software events log.
Example: CAE=
Note: This command takes no arguments
CAE=
CAE?
CAE*
CAE#
N/A N/A
Circuit ID
String
CID= 24 bytes Command or Query.
Sets or queries the user-defined Circuit ID string, which is a fixed
length of 24 characters.
Valid characters include:
Space ( ) * + – , . / 0 9 and A thru Z
CID=
CID?
CID*
CID#
CID? CID=xxxxxxxxxxxxxxxx
xxxxxxxx