Product specifications

CDM-710 Broadcast Satellite Modem Revision 10
Remote Control MN/CDM710.IOM
A–46
Parameter
Type
Command
(Instruction
Code and
Qualifier)
Arguments
for Command
or Response
to Query
Description of Arguments
Response
to
Command
Query
(Instruction
Code and
Qualifier)
Response to Query
Retrieve next 5
unread Stored
Events
N/A 75 bytes Query Only.
Unit returns the oldest 5 Stored Events which have not yet been
read over the remote control. Reply format: {CR}Sub-
body{CR}Sub-body{CR}Sub-body{CR}Sub-body{CR}Sub-
body, where Sub-body= ABCddmmyyhhmmss,
A being the fault/clear indicator.
F=Fault
C=Clear
I=Info
B being the fault type where:
1=Unit
2=Rx Traffic
3=Tx Traffic
4=Log
C is Fault Code numbers, as in FLT? or Info Code, which is:
0=Power Off
1=Power On
2=Log Cleared
3=Global Config Change
4=Redundancy Config Change
If there are less than 5 events to be retrieved, the remaining
positions are padded with zeros.
If there are no new events, the response is RNE*.
RNE?
RNE*
RNE#
RNE? RNE={CR}ABCddmmy
yhhmmss{CR}ABCddm
myyhhmmss{CR}ABCd
dmmyyhhmmss{CR}AB
Cddmmyyhhmmss
{CR}ABCddmmyyhhm
mss
Serial Number N/A 9 bytes Query Only.
Used to query the unit 9-digit serial number. Unit returns its S/N
in the form xxxxxxxxx.
Example: SNO=176500143
SNO?
SNO*
SNO#
SNO? SNO=xxxxxxxxx