Product specifications

CDM-710 Broadcast Satellite Modem Revision 10
Remote Control MN/CDM710.IOM
A–41
Parameter
Type
Command
(Instruction
Code and
Qualifier)
Arguments
for Command
or Response
to Query
Description of Arguments
Response
to
Command
Query
(Instruction
Code and
Qualifier)
Response to Query
Firmware
Revisions
N/A 1 byte Query Only.
Query the version information of the system. Where:
i = Bulk Image number (1 or 2)
a = Firmware Image
b = Firmware Revision
c = Firmware Date
Example: FRW?1
FRW?
FRW*
FRW#
FRW?i FRW={CR}Boot:{CR}a,
b,c{CR}Bulki:{CR}a,b,c
{CR}a,b,c…
Gigabit Egress
FEC Enable
GEF= 2 bytes Command or Query.
Gigabit Egress FEC Enable/Disable.
s=Slot (1, 2)
n=Enable / Disable, where
0 = Disabled
1 = Enabled
GEF=
GEF#
GEF?
GEF*
GEF?s GEF=sn
Gigabit Egress
Multicast
Group Address
GEG= 16 bytes Command or Query.
Gigabit Egress Multicast Group Address. The multicast stream
egressing from the gigabit interface will have this ip address as
the source IP address.
s=Slot (1, 2)
i=IP Address
GEG=
GEG#
GEG?
GEG*
GEG?s GEG=siii.iii.iii.iii
Gigabit Egress
Port Numbers
GEP= 11 bytes Command or Query.
Gigabit Egress Port Numbers
s=Slot (1, 2)
nnnnn = Source Port Number (0 – 65535)
ppppp = Destination Port Number (0 – 65535)
*** Note: Both Source Port and Destination Port must be valid
for set command to take effect.
GEP=
GEP#
GEP?
GEP*
GEP?s GEP=snnnnnppppp