Product specifications

CDM-710 Broadcast Satellite Modem Revision 10
Remote Control MN/CDM710.IOM
A–33
Parameter
Type
Command
(Instruction
Code and
Qualifier)
Arguments
for Command
or Response
to Query
Description of Arguments
Response
to
Command
Query
(Instruction
Code and
Qualifier)
Response to Query
Rx Clock
Invert
RCI=
2 bytes
Command or Query.
Invert Receive Clock, where:
s=Defines which interface slot ( 1 or 2 )
x=Invert Receive Clock, where:
0=Normal
1=Inverted
(Note: Command valid Only with HSSI)
Example: RCI = 11 (selects Inverted RX Clock, Slot 1)
RCI =
RCI?
RCI *
RCI #
RCI?s
RCI =sx
(see description of
arguments)
Rx Clock
Source
RCK=
2 bytes
Command or Query.
Rx Clock Source (For Data Rate Accuracy), where:
s=Defines which interface slot ( 1 or 2 )
x=Rx Clock Source, where:
0=Rx Satellite
1=Tx-Terrestrial
2=External Reference Clock
3=Internal (HSSI Only)
Example: RCK=11 (selects Tx-Terrestrial)
RCK=
RCK?
RCK*
RCK#
RCK?s
RCK=sx
(see description of
arguments)
Enable/Disable
Adaptive
Equalizer
AEQ= 1 byte Command or Query.
Adaptive Equalizer status, where:
0=Disable
1=Enable
Example: AEQ=1 (which is Enable)
AEQ=
AEQ?
AEQ*
AEQ#
AEQ? AEQ=x
Eb/No Alarm
Point
EBA= 4 bytes Command or Query.
Eb/No alarm point in dB, with a range between 0.1 and 16 dB.
Resolution=0.1 dB
Example: EBA=12.3
EBA=
EBA?
EBA*
EBA#
EBA? EBA=xx.x
(see description of