Product specifications

CDM-710 Broadcast Satellite Modem Revision 10
Remote Control MN/CDM710.IOM
A–32
Parameter
Type
Command
(Instruction
Code and
Qualifier)
Arguments
for Command
or Response
to Query
Description of Arguments
Response
to
Command
Query
(Instruction
Code and
Qualifier)
Response to Query
Rx Frame Size N/A 1 byte Query Only.
Rx Frame Size Long/Short selection, where:
0=Short,
1=Long
Example: RFS =0 (which is Short Frame Size)
*NOTE: Setting only valid in DVB-S2 mode. If the unit is not
locked, the query returns ‘x’.
RFS?
RFS *
RFS #
RFS? RFS =x
Rx Pilot On/Off N/A 1 byte Command or Query.
Rx Pilot On/Off selection, where:
0=Off,
1=On
Example: RPI=0 (which is Pilot Off)
*NOTE: Only valid in DVB-S2 mode. This is automatically
detected on demod acquisition, but if the unit is not locked, the
query returns ‘x’.
RPI=
RPI?
RPI*
RPI#
RPI? RPI=x
Rx Data Invert
RDI=
2 bytes
Command or Query.
Invert Receive Data, where:
s=Defines which interface slot ( 1 or 2 )
x=Invert Receive Data, where:
0=Normal
1=Inverted
(Note: Command valid Only with HSSI.)
Example: RDI = 11 (selects Inverted RX Data)
RDI =
RDI?
RDI*
RDI#
RDI?sc
RDI =sx
(see description of