Product specifications

CDM-710 Broadcast Satellite Modem Revision 10
Remote Control MN/CDM710.IOM
A–24
Parameter
Type
Command
(Instruction
Code and
Qualifier)
Arguments
for Command
or Response
to Query
Description of Arguments
Response
to
Command
Query
(Instruction
Code and
Qualifier)
Response to Query
Local/Remote
Status
LRS= 1 byte Command or Query.
Local/Remote status, where:
0=Local
1=Serial
2=Reserved
3=Ethernet
Example: LRS=1 (which is remote Serial)
LRS=
LRS?
LRS*
LRS#
LRS? LRS=x
Unit MAC
Address
N/A 12 bytes Query Only.
MAC address of the unit, reported in hexadecimal.
Example: MAC=0006B000D2A7 (The MAC address of the unit
is 00:06:B0:00:D2:A7 )
MAC?
MAC*
MAC#
MAC? MAC=AABBCCDDEEFF
Unit Alarm
Mask
MSK= 2 bytes Command or Query.
Alarm mask conditions, in form ab, where:
a=Tx AIS (0 = Alarm, 1 =Fault, 2 = Masked)
b=Spare
Example: MSK = 00
MSK=
MSK?
MSK*
MSK#
MSK? MSK=ab
Number of
Unread stored
Events
N/A 3 bytes Query Only.
Unit returns the Number of stored Events, which remain Unread,
in the form xxx.
Note: This means unread over the remote control.
Example: NUE=126
NUE?
NUE*
NUE#
NUE? NUE=xxx
Soft Reboot RBT=1 1 byte Command Only.
Soft Reboot.
1= Reboot System
RBT?
RBT*
RBT#
N/A RBT=
Enable
Redundancy
Switch Mode
ESW= 1 byte, value
of 0 or 1
Command or Query.
Set redundancy mode, where :
0 = Disable
1 = Enable
Example: ESW=1 (Enable redundancy mode)
ESW=
ESW?
ESW*
ESW#
ESW? ESW=x