Product specifications

CDM-710G High-Speed Satellite Modem Revision 1
Remote Control MN-CDM710G
A–25
Parameter
Type
Command
(Instruction
Code and
Qualifier)
Arguments for
Command or
Response to
Query
Description of Arguments
Response to
Command
Query
(Instruction
Code and
Qualifier)
Response to Query
Rx FEC Type N/A 1 byte Query Only.
Rx FEC coding type, where:
1=LDPC
( FEC is dependent on the RX Mode Type. )
Example: RFT=1 (which is LDPC coding)
RFT?
RFT*
RFT#
RFT? RFT=x
Rx Gold Code
Sequence Index
RGS= 6 bytes Command or Query.
Rx Gold Code Sequence Index:
xxxxxx = Gold Code Sequence index ( 0 to 262141 )
Example: RGS=189063
RGS=
RGS?
RGS*
RGS#
RGS? RGS=xxxxxx
Rx Interface
Enable
RIE= 2 bytes Command or Query.
Interface Slot Enable/Disable, where:
s=Defines which interface slot (1 or 2)
x=Rx Interface Status, where:
0=Disabled
1=Enabled
Example: RIE =11 (Enables receive interface)
RIE=
RIE?
RIE*
RIE#
RIE?s RIE=sx
Retrieve next 5
unread Stored
Events
N/A 75 bytes Query Only.
Unit returns the oldest 5 Stored Events which have not yet been read over
the remote control in the form: {CR}Sub-body{CR}Sub-body{CR}Sub-
body{CR}Sub-body{CR}Sub-body, where Sub-body= ABCddmmyyhhmmss,
A being the fault/clear indicator.
F=Fault
C=Clear
I=Info
B being the fault type where:
1=Unit
2=Rx Traffic
3=Tx Traffic
4=Log
C is Fault Code numbers, as in FLT? or Info Code, which is:
0=Power Off
1=Power On
2=Log Cleared
3=Global Config Change
4=Redundancy Config Change
If there are less than 5 events to be retrieved, the remaining positions are
padded with zeros. If there are no new events, the response is RNE*.
RNE?
RNE*
RNE#
RNE? RNE={CR}ABCddmmyyh
hmmss{CR}ABCddmmyy
hhmmss{CR}ABCddmm
yyhhmmss{CR}ABCddm
myyhhmmss
{CR}ABCddmmyyhhmm
ss
Rx Pilot On/Off N/A 1 byte Query.
Rx Pilot On/Off selection, where:
0=Off,
1=On
Example: RPI=0 (which is Pilot Off)
*NOTE: This is automatically detected on demod acquisition, but if the unit
is not locked, the query returns ‘x’.
RPI?
RPI*
RPI#
RPI? RPI=x