Product specifications

CDM-710G High-Speed Satellite Modem Revision 1
Remote Control MN-CDM710G
A–10
Parameter
Type
Command
(Instruction
Code and
Qualifier)
Arguments for
Command or
Response to
Query
Description of Arguments
Response to
Command
Query
(Instruction
Code and
Qualifier)
Response to Query
Faults and
Status (cont.)
I=Tx Ais Interface 1
J=Tx Ais Interface 2
K=Tx Cable Interface 1
L=Tx Cable Interface 2
c=Rx Traffic Status
0=No faults
d=New Faults
0=No new faults
1=New faults, since last check
Gateway
Address
IPG= 15 bytes Command or Query.
Used to set the Gateway IP addess for the 10/100 Base Tx Ethernet
management port, in the format:
xxx.xxx.xxx.xxx, where:
xxx.xxx.xxx.xxx is the IP address
Example: IPG = 010.006.030.001
IPG=
IPG?
IPG*
IPG#
IPG? IPG = xxx.xxx.xxx.xxx
Interface Type N/A 2 bytes Query Only.
Interface Type, where:
s=Defines which interface slot (1 or 2)
x=Defines the interface type, where:
0=Reserved
1=Reserved
2=Gigabit Ethernet
3=HSSI
4=E3T3STS1
Example: ITF?1
ITF?
ITF*
ITF#
ITF?s ITF=sx
Local/Remote
Status
LRS= 1 byte Command or Query.
Local/Remote status, where:
0=Local
1=Serial
2=Reserved
3=Ethernet
Example: LRS=1 (which is remote Serial)
LRS=
LRS?
LRS*
LRS#
LRS? LRS=x
Unit MAC
Address
N/A 12 bytes Query Only.
MAC address of the unit, reported in hexadecimal.
Example: MAC=0006B000D2A7
(The MAC address of the unit is 00:06:B0:00:D2:A7 )
MAC?
MAC*
MAC#
MAC? MAC=AABBCCDDEEFF
Number of
Unread stored
Events
N/A 3 bytes Query Only.
Unit returns the Number of stored Events, which remain Unread, in the
form xxx.
Note: This means unread over the remote control.
Example: NUE=126
NUE?
NUE*
NUE#
NUE? NUE=xxx