Product specifications

CDM-710 Broadcast Satellite Modem Revision 11
Front Panel Operation MN/CDM710.IOM
5–34
(CONFIG: Intfc2 Gigabit Ethernet) Egress Æ FEC Æ Matrix
Intfc2 Egress FEC Matrix:
Length = 10, Depth = 10
To configure the dimension of the egress FEC matrix, first use the arrow keys to
select the desired digit to edit, then use the arrow keys to change the value of that
digit. Press
ENTER when done.
Valid values for Length and Depth are as follows:
L * D 100
1 L 20
4 D 20
(CONFIG: Intfc2 Gigabit Ethernet) Egress Æ IP
Intfc2 Egress IP:
Group SrcPort DestPort
To allow configuration of IP header fields for the egress packets, select Group, ScrPort, or
DestPort using the arrow keys, then press
ENTER.
(CONFIG: Intfc2 Gigabit Ethernet) Egress Æ IP Æ Group
Intfc2 Egress Multicast:
239.010.010.010 ()
To enter a valid destination IP Multicast Group Address for egress IP packets, first use
the arrow keys to select the desired digit to edit, then use the arrow keys to
change the value of that digit. Press
ENTER when done.
(CONFIG: Intfc2 Gigabit Ethernet) Egress Æ IP Æ SrcPort
Intfc2 Egress Src Port:
01024 ()
To enter a valid UDP Source Port Address for the network, first use the arrow keys
to select the desired digit to edit, then use the arrow keys to change the value of
that digit. Press
ENTER when done.
(CONFIG: Intfc2 Gigabit Ethernet) Egress Æ IP Æ DestPort
Intfc2 Egress Multicast:
01024 ()
To enter a valid UDP Destination Port Address for the egress packet stream, first use the
arrow keys to select the desired digit to edit, then use the arrow keys to
change the value of that digit. Press
ENTER when done.