Product specifications
CDM-710 Broadcast Satellite Modem Revision 11
Front Panel Operation MN/CDM710.IOM
5–23
(CONFIG: Rx) Eb/No
Eb/No Alarm: Threshold
Alarm/Fault (E)
Select Threshold, Alarm/Fault, or Masked using the W X arrow keys, then press ENTER.
(CONFIG: Rx) Eb/No Æ Threshold
Eb/No Alarm Threshold:
2.0 dB Masked (▲ ▼ E)
The range of Eb/No alarm point values is from 0.1 to 16.0 dB. If the Eb/No falls below the
selected value, a receive traffic fault is generated.
To edit the threshold, use the
W X arrow keys to select the digit to be edited, then use the ▲ ▼
arrow keys to change the value of that digit. Press
ENTER when done.
(CONFIG: Rx) Eb/No Æ Alarm/Fault
Eb/No Alarm:
Alarm Fault Mask (E)
The available choices define the Eb/No Alarm as an Alarm, as a Fault, or to completely
Mask the alarm. This choice affects operation in 1:1 redundancy.
Select Alarm, Fault, or Masked using the
W X arrow keys, then press ENTER.
(CONFIG: Rx) PLL
Carrier PLL Bandwidth:
1x 2x (E)
This selection is sometimes useful when high phase noise is present. Select 1x or 2x using the W X
arrow keys, then press
ENTER. 1x is the normal operating mode.