Product specifications
CDM-710 Broadcast Satellite Modem Revision 11
Front Panel Operation MN/CDM710.IOM
5–10
(CONFIG: Remote) Ethernet Æ Address
Ether IP Address/Range:
192.168.001.001/24 ()
To edit the IP Address/Range, use the W X arrow keys to first select the digit to be edited, then
use the
ST arrow keys to change the value of that digit. The range is adjustable from 08 to
30. Press
ENTER when done.
(CONFIG: Remote) Ethernet Æ MAC
M&C Port MAC Address:
00-06-B0-00-56-33
This screen is ‘status only’ – Press ENTER or CLEAR to return to the previous menu.
Note: The preceding address is representative of a typical MAC address.
(CONFIG: Remote) Ethernet Æ SNMP
SNMP:
Community Traps (LRE)
Submenus enable viewing of the Community read string, or setting of the destination IP address
for SNMP traps. Select Community or Traps using the
W X arrow keys, then press ENTER.
(CONFIG: Remote) Ethernet Æ SNMP Æ Community
SNMP Community:
Read ( E )
Select Read using theST arrow keys, then press ENTER.
(CONFIG: Remote) Ethernet Æ SNMP Æ Community Æ Read
Read Community: ( E )
public
To edit the SNMP Read Community string, use the ◄ ► arrow keys to select the
character to edit, then use the
▲ ▼ arrow keys to edit that character.
Note: Only the first 20 characters on the bottom line are available.
All printable ASCII characters are available with the exception of the backslash ( /
ASCII code 92) and tilde (~ ASCII code 126).
Once the string has been composed, press ENTER. All trailing spaces are removed
from the Read Community string upon entry.