Product specifications

CDM-710 Broadcast Satellite Modem Revision 11
Front Panel Operation MN/CDM710.IOM
5–9
(CONFIG: Remote) Serial Æ Interface Æ RS232
In RS232 Mode the Bus
Address is fixed at 0000
As per the displayed message, the Bus Address is fixed and not editable in RS232 mode.
Press
ENTER or CLEAR to return to the previous menu.
(CONFIG: Remote) Serial Æ Interface Æ RS485-2W, -4W
RS485 Mod Address: 0001
(E)
To edit the RS485 address of the modem, use the W X arrow keys to select the digit to be
edited, then use the
ST arrow keys to change the value of that digit. The valid range of
addresses is from 0001 to 9999. Press
ENTER when done.
(CONFIG: Remote) Serial Æ Interface Æ Baudrate
Local M&C Bus Baud Rate:
9600 Baud ( E )
To select the baud rate of the remote control bus connected locally to the M&C computer,
use the
ST arrow keys to select the desired rate, then press ENTER. Baud rates of 1200,
2400, 4800, 9600, 19200, 38400, and 57600 baud are selectable.
Note: The Asynchronous character format is FIXED at 8 data bits, No parity, and 1 stop bit
(8-N-1).
(CONFIG: Remote) Ethernet
Ethernet CONFIG: Gateway
Address MAC SNMP ( E)
Select Gateway, Address, MAC, or SNMP using the W X arrow keys, then press ENTER.
(CONFIG: Remote) Ethernet Æ Gateway
Ethernet IP Gateway:
063.168.001.127 ( E )
To edit the IP Gateway address, use the arrow keys to first select the digit to be edited,
then use the ST arrow keys to change the value of that digit. Press
ENTER when done.