Product specifications
CDM-710 Broadcast Satellite Modem Revision 11
Flash Upgrading MN/CDM710.IOM
4–5
9
(cont)
The process sequences through several blocks – this will take several minutes.
Programming flash sector #xx
Please wait…
IMPORT ANT
• Stopping the FTP before the “PROGRAMMING FLASH SECTOR#xx PLEASE
WAIT” messaging sequence is complete could lead to an incomplete
download, and will require a repeat of Step 9.
• The user must reflash both images with the same firmware version for the
unit to function properly.
•
The upgrade from an earlier version to 4.x.x is a one-way upgrade path. Once
an upgrade to 4.0.1 is completed it is no longer possible to revert to earlier
versions. If reflash to an earlier version is attempted, the modem will detect
and disallow it as a protective measure. The unit will also disallow an attempt
to switch to an image with an earlier version of firmware.
10
Verify the file transfer:
The PC should report that the file transfer has occurred, and the display on the modem will report:
Bulk FTP done. Press CLEAR.
11
Terminate the FTP session:
Type "bye" and close the Command-line window.
12
Confirm that the new file was loaded by using the procedure in Step 1.
13
Change the desired image to boot.
From the CDM-710 front panel menu:
SELECT: UTIL Æ Firmware Æ Select (use ◄ ► arrows
to change to the other image), then cycle power to reboot the modem.
14
Verify the new firmware has booted by observing the Firmware Version displayed on the modem
front panel VFD (Video Fluorescent Display):
CDM-710 Modem
Firmware Version: #.#.#
Note: To load the second image, repeat Steps 8 through 11.
4.4 10/100/1000 BASE-T (GigE) INTERFACE (CDI-70) FTP Upload Procedure
If a CDI-70 10/100/1000 Base-T Gigabit Ethernet Interface is used, a CDM-710/710L modem
running Firmware Ver. 4.1.6 requires a CDI-70 Interface running Firmware Ver. 1.1.2 or higher.
Refer to Chapter 10. 10/100/1000 BASE-T (GigE) INTERFACE (CDI-70) for information on
and instructions for flash upgrading this optional data interface.
4.5 USB Procedure
USB reflash is not available in this firmware release – please consult Comtech