Product specifications

CDM-710 Broadcast Satellite Modem Revision 11
Appendix A MN/CDM710.IOM
A–24
Parameter
Type
Command
(Instruction
Code and
Qualifier)
Arguments for
Command or
Response to
Query
Description of Arguments
Response to
Command
Query
(Instruction
Code and
Qualifier)
Response to Query
Faults and
Status
N/A 5 bytes Query only.
Unit returns the current fault and status codes for the Unit (hardware), Tx Traffic
and Rx Traffic, in the form abcd, where:
a = Unit Faults:
0=No faults
1=Framer FPGA Load
2=Power supply fault, +1.5 Volts, Framer Card
3=Power supply fault, +1.5 Volts, Interface #1
4=Power supply fault, +1.5 Volts, Interface #2
5=Power supply fault, +3.3 Volts, Framer Card
6=Power supply fault, +5.0 Volts, Framer Card
7=Power supply fault, +12.0 Volts, Framer Card
8=Power supply fault, -12.0 Volts, Framer Card
9=Power supply fauilt, +18.0 Volts, Framer Card
A=FLASH Checksum
B=FEC1 Load
C=FEC2 Load
D=Interface #1 Load
E=Interface #2 Load
F=192 MHz PLL
G=External Reference
H=Framer Card Temperature
I=Modem Temperature
J=Cooling Fans
K=Interface #1 Removed
L=Interface #2 Removed
b = Tx Traffic Status:
0=No faults
c=Rx Traffic Status
0=No faults
1=+1.5V Demod Power Supply Unit (Demodulator Card)
2=FPGA Load (Demodulator Card)
3=Demod Unlocked
4=DSNG Sync Error
5=FPGA Temperature (Demodulator Card)
6=Reserved
7=AGC Level Out of Range
8=Eb/No Limit Exceeded
9=Demodulator Synth 1 PLL
A=Demodulator Synth 2 PLL
B= SERDES Demod to Framer
C= SERDES Framer to FEC1
D= SERDES Framer to FEC2
E=Reserved
F= MPEG transport stream error.
FLT?
FLT*
FLT#
FLT? FLT=abcd
d=Change in fault status
since last poll.
Note: Each section has faults
listed in order of priority. For
each section, only the highest
priority fault is returned. There
maybe multiple faults for each
section, but only the highest
fault is returned.