Product specifications
CDM-710 Broadcast Satellite Modem Revision 11
Appendix A MN/CDM710.IOM
A–15
Parameter
Type
Command
(Instruction
Code and
Qualifier)
Arguments for
Command or
Response to
Query
Description of Arguments
Response to
Command
Query
(Instruction
Code and
Qualifier)
Response to Query
Retrieve next 5
unread Stored
Events
N/A 75 bytes Query only.
Unit returns the oldest 5 Stored Events which have not yet been read over the
remote control in the form {CR}Sub-body{CR}Sub-body{CR}Sub-body{CR}Sub-
body{CR}Sub-body, where Sub-body= ABCddmmyyhhmmss is as follows:
A being the fault/clear indicator.
F=Fault
C=Clear
I=Info
B being the fault type where:
1=Unit
2=Rx Traffic
3=Tx Traffic
4=Log
C is Fault Code numbers, as in FLT? or Info Code, which is:
0=Power Off
1=Power On
2=Log Cleared
3=Global Config Change
4=Redundancy Config Change
If there are less than 5 events to be retrieved, the remaining positions are
padded with zeros. If there are no new events, the response is RNE*.
RNE?
RNE*
RNE#
RNE? RNE={CR}ABCddmmyyhhmm
ss{CR}ABCddmmyyhhmmss{
CR}ABCddmmyyhhmmss{CR}
ABCddmmyyhhmmss
{CR}ABCddmmyyhhmmss
Tx ASI
Bandwidth
TAB=
2 bytes Command or Query.
Tx ASI Bandwidth in the form sx, where:
s=Defines which interface slot (1 or 2)
x=Defines ASI Bandwidth, where:
0=Wide
1=Narrow
Example: TAB=11 (Narrow bandwidth selected)
TAB=
TAB?
TAB*
TAB#
TAB?s
TAB=sx
Tx Alpha Rolloff
TAR= 1 byte Command or Query.
Tx Alpha Rolloff in the form x, where:
0 = 20%
1 = 25%
2 = 35%
Example: TAR=0 (Tx Alpha Rolloff of 20% selected)
TAR=
TAR?
TAR*
TAR#
TAR? TAR=x
Tx Cloc
k
Invert
TCI=
2 bytes
Command or Query.
Invert Transmit Clock, where:
s=Defines which interface slot ( 1 or 2 )
x=Invert Transmit Clock, where:
0=Normal
1=Inverted
Note: Command valid Only with HSSI)
Example: TCI = 11 (Inverted TX Clock, Slot 1 selected)
TCI =
TCI?
TCI *
TCI #
TCI?s
TCI =sx
(See Description of
Arguments)