Product specifications
CDM-710 Broadcast Satellite Modem Revision 11
Appendix A MN/CDM710.IOM
A–13
Parameter
Type
Command
(Instruction
Code and
Qualifier)
Arguments for
Command or
Response to
Query
Description of Arguments
Response to
Command
Query
(Instruction
Code and
Qualifier)
Response to Query
Gigabit Stream
Timeout
GTO= 3 bytes Command or Query.
Gigabit Stream Timeout (Only used when in Dual Stream Mode) in the form stt,
where:
s=Slot (1, 2)
t=Timeout in 100 mS intervals (0 – 10)
GTO=
GTO#
GTO?
GTO*
GTO?s GTO=stt
Initialize Events
Pointer
IEP= None Command only.
Resets internal pointer to allow RNE? queries to start at the beginning of the
stored events log.
IEP=
IEP?
IEP*
IEP#
N/A N/A
Boot Image
IMG= 1 byte Command only.
Boot image selection, where n is the image number:
1=Image #1
2=Image #2
Example: IMG=1 (Image #1 selected for booting.)
IMG=
IMG?
IMG*
IMG#
IMG? IMG=n
Tx Output
Impendance
IMP= 1 byte Command or Query.
Tx output impedance in the form x, where:
0=50 Ohm
1=75 Ohm
Example: IMP=0 (Impedance set to 50 Ohms)
Note: Setting Tx Impedence is only possible on 70/140 MHz units.
IMP=
IMP?
IMP*
IMP#
IMP? IMP=x
IP Address
IPA= 18 bytes Command or Query.
Used to set the IP address and network prefix for the 10/100 BaseTx Ethernet
management port, in the form xxx.xxx.xxx.xxx.yy, where:
xxx.xxx.xxx.xxx is the IP address
yy is the network prefix (00..31)
Example: IPA=010.006.030.001.24
IPA=
IPA?
IPA*
IPA#
IPA? IPA= xxx.xxx.xxx.xxx.yy
Gateway
Address
IPG= 15 bytes Command or Query.
Used to set the Gateway IP addess for the 10/100 Base Tx Ethernet
management port, in the form xxx.xxx.xxx.xxx, where:
xxx.xxx.xxx.xxx is the IP address
Example: IPG = 010.006.030.001
IPG=
IPG?
IPG*
IPG#
IPG? IPG = xxx.xxx.xxx.xxx
Interface Type
N/A 2 bytes Query only.
Interface Type in the form sx, where:
s=Defines which interface slot (1 or 2)
x=Defines the interface type, where:
0=ASI
1=Gigabit Ethernet
2=HSSI
Example: ITF?1
ITF?
ITF*
ITF#
ITF?s ITF=sx