6.3 SNMP Interface
The Simple Network Management Protocol (SNMP) is an application-layer protocol designed to
facilitate the exchange of management information between network devices. The CDM-710
SNMP agent supports both SNMPv1 and v2c.
IMPORTANT
For proper SNMP operation, the CDM-710 MIB files must be used with the
associated version of the CDM-710 modem M&C. Please refer to the CDM-710
FW Release Notes for information on the required FW/SW compatibility.
6.3.1 Management Information Base (MIB) Files
MIB files are used for SNMP remote management and consist of Object Identifiers (OIDs). Each
OID is a node that provides remote management of a particular function. A MIB file is a tree of
nodes that is unique to a particular device.
The following MIB files are associated with the CDM-710:
MIB File/Name Description
FW10874-2-.mib
ComtechEFData Root MIB
file
ComtechEFData MIB file gives the root tree for ALL Comtech EF Data products and consists of
only the following OID:
Name: comtechEFData
Type: MODULE-IDENTITY
OID: 1.3.6.1.4.1.6247
Full path: iso(1).org(3).dod(6).internet(1).private(4).enterprises(1).comtechEFData(6247)
Module: ComtechEFData
FW12438-2B.mib
CDM-710
Common MIB file
CDM-710 High Speed modem family common components.
Fw12051-4-.mib
CDM-710-Modulator
MIB file
CDM-710 High Speed modem family Modulator components.
Fw12051-5-.mib
CDM-710 ASI MIB file
CDM-710 High Speed modem family ASI interface components.
Fw12051-6-.mib
CDM-710 REDUNDANCY
MIB file
CDM-710 High Speed modem family 1:1 Redundancy components.
FW12438-3A.mib
CDM-710 Traps MIB file
CDM-710 High Speed modem family Trap MIB file is provided for SNMPv1 traps
Fw12051-8-.mib
CDM-710 Gigabit Ethernet
Interface MIB file
CDM-710 High Speed modem family Gigabit Ethernet MIB file is provided for SNMPv1 traps
These MIB files should be compiled in a MIB Browser or SNMP Network Monitoring System server.
Note: The SNMP agent supports both “SNMPv1” and “v2c”. The “Traps” file only needs to be