Product specifications

CDM-710 Broadcast Satellite Modem Revision 11
Front Panel Operation MN/CDM710.IOM
5–46
5.3.3.2 (Test:) TestPatterns
The availability of test patterns depends on the installed, enabled interface. The example for the
menu that is displayed if the CDI-40 ASI interface is installed in Slot 1, or the CDI-70 Gigabit
Ethernet Interface is installed in Slot 2, is as follows:
Test Pattern Subst:
Off 2047 2^23-1
Select Off, 2047, or 2^23-1 using the W X arrow keys, then press ENTER.
If, however, the CDI-60 HSSI Interface is installed and enabled in Slot 1, the following message
displays:
Test Pattern Subst:
N/A on HSSI Intfc
Press ENTER or CLEAR to return to the previous menu.
5.3.4 SELECT: Info
INFO: Rem Tx Rx
Intfc1 (E)
Select a submenu from the Info: menu branch – Rem, Tx, Rx, Intfc1, or Intfc2 – using the W X
arrow keys, then press
ENTER.
Note: INFO screens provide read-only information on the current configuration of the modem
without risking inadvertent changes. The user may only view, but not edit, an Info screen.
5.3.4.1 (INFO:) Rem
Remote M&C: 100BaseTx
IP Addr: 192.168.001.006
This display provides the status, as applicable, of the Remote Monitor & Control configuration.