Product specifications
CRS-170A L-Band 1:1 Redundancy Switch Revision 3
Modem and Switch Configuration MN/CRS170A.IOM
6. Connect all cables – including the control cable, IF cable and data cables – to the
modems and the CRS-170A. Additionally, both modems will need an Ethernet connection
to each other through a Layer 2 switch. For detailed information, refer to Chapter 4.
CABLES AND CONNECTIONS.
7. Power up both CDM-7x0s. The modems will now come up in a redundant mode of
operation. Verify that one modem is
ONLINE by the front panel LEDs; also verify that
the
ONLINE LEDs for the CRS-170A indicate the same online state as the modems.
All configuration changes can only be made to the Online CDM-7x0
and will require the user to “
S
ave Parameters to permanent
storage
” to ensure the configuration change is also applied to the
Backup CDM-7x0.
3.4.2 Non-IP Redundancy Configuration
If the terrestrial data type non Ethernet (i.e. HSSI, G.703), the modem configuration procedure is
as follows:
1. On both modems, set the redundancy to the Enable state:
CONFIG Æ AUX (Redundancy Mode) Æ ENA/DIS set to Enable.
2. Connect all cables – including the control cable, IF cable and data ‘Y’cables – to the modems
and the CRS-170A as directed in Chapter 4. CABLES AND CONNECTIONS.
3–7