Product specifications
CRS-170A L-Band 1:1 Redundancy Switch Revision 3
Modem and Switch Configuration MN/CRS170A.IOM
3–6
3.4 Configuring CDM-7x0s for 1:1 Redundancy
IMPORTA T
•
N
For correct operation of the CRS-170A, the CDM-700 and CDM-710 modems
must have the following installed:
For the CDM-700:
► Firmware Version 1.1.6 (or higher)
► Hardware Revision A (chassis with round-buttoned keypad)
• For the CDM-710:
► Firmware Version 2.4.1 (or higher)
► Hardware Revision A (chassis with round-buttoned keypad)
If the modem does not meet this requirement, contact Comtech EF Data.
Flash firmware upgrades are free and may be downloaded from the CEFD
Web page. Hardware revision upgrades must be performed at CEFD.
NOTE: Hardware upgrades are possible only for the Rev. A chassis and later
versions of the CDM-700/710 – 1:1 redundancy operation is not available with
hardware prior to Rev. A.
The User can fully configure, monitor, and control the modem operation from the modem’s front
panel; via the keypad and display, nested menus displaying all available options are used and
prompt the User to carry out a required action.
Refer to the CDM-700 or CDM-710 Installation and Operation Manual for detailed
configuration information.
3.4.1 IP Redundancy Configuration
If the terrestrial data type is GigE, follow the steps outlined in this procedure:
1. Before connecting the modems to the CRS-170A, you will need to first configure the
following IP module settings on the CDM-7x0. From the CDM-7x0 front panel:
CONFIG Æ AUX (Redundancy Mode) Æ ENA/DIS set to Disable.
2. On both modems, enter a unique IP Address that is on the same subnet:
CONFIG Æ REMOTE Æ ETHERNET Æ ADDRESS
3. On both modems, enter a unique IP Address for the CDI-70 (GigE Interface) that is on the
same subnet:
For the CDM-700:
CONFIG Æ Intfc1 Æ MAN Æ ADDRESS
For the CDM-710:
CONFIG Æ Intfc2 Æ MAN Æ ADDRESS
4. On both modems, set the redundancy to the Enable state:
CONFIG Æ AUX (Redundancy Mode) Æ ENA/DIS set to Enable.
Press
ENTER to save parameters to flash memory
5. Power down both CDM-7x0s.