Product specifications

CDD-880 Multi Receiver Router Revision 0
Ethernet Management MN-CDD880
5–25
Input Port Status
This read-only section provides, on an active demod basis, an overall tally of the parameters
compiled since the logging buffer was last cleared. For each active demodulator, note the
following:
Lock – VersaFEC decoder lock.
Eb/No (dB) – Estimated channel noise level.
Estimated Corrected BER – Bit Error Rate after VersaFEC decoding.
RSSI (dB) – Relative Signal Strength Indicator (0 – 60 dB of demod’s operating range).
Rx Freq Offset – Estimated offset from demod’s configured frequency (in Hz).
Events
Each event or alarm is logged, date- and time-stamped, and a Description is provided.
Click [Clear Event Table] to delete all existing log entries from the Router Events Log. The log
is then reset to one (1) entry: “Info: Log Cleared”.