Product specifications
CDD-880 Multi Receiver Router Revision 0
Rear Panel Connector Pinouts MN-CDD880
3–5
3.5 Power / Ground Connections
3.5.1 Alternating Current (AC) Power Connector (Standard)
IMPOR TANT
For continued operator safety, always replace the fuses with the correct type
and rating.
A standard, detachable, non-locking, 3-prong power cord (IEC plug)
supplies the Alternating Current (AC) power to the CDD-880. The
IEC line input connector contains the ON/OFF switch for the unit. It
also is fitted with two fuses, one each for line and neutral
connections (or L1, L2, where appropriate). These are contained
within the body of the connector, behind a small plastic flap.
Observe the following:
AC Power Specifications
Input Power 40W maximum, 20W typical
Input Voltage
100 - 240 volts AC, +6%/-10% - autosensing
(total absolute max. range is 90 - 254 volts AC)
Connector Type IEC
Fuse Protection
T3.15A Slow-blow (for 120/230 volt AC operation)
Line and neutral fusing
20 mm type fuses
3.5.2 Ground Connector
A #10-32 stud is provided on the unit rear panel for connection of a common chassis
ground among equipment.