Product specifications

CDD-880 Multi Receiver Router Revision 0
Introduction MN-CDD880
1–8
1.4 Summary of Specifications
1.4.1 Demodulator
Specification Parameters
Frequency Range 950
to 2150 MHz
Input Type ‘N’ female connector
Input Impedance
50
Ω
, 17 dB minimum return loss
Input Power Range -130 + 10 log(symbol rate) to -80 + 10 log(symbol rate) dBm (see Figure 1-6)
Maximum Composite Operation Level
102
10 log(symbol rate, desired carrier) dBC, +10 dBm max, with the additional
requirement that within ±10 MHz of the desired carrier, composite power is +30 dBC.
Absolute Maximum, No Damage +20 dBm
Adaptive Equalizer 5-tap design, selectable on/off
Acquisition Range Fixed acquisition range of ± Rs/2 = receive symbol rate / 2
Clock Tracking Range ± 100 ppm min
Acquisition Range +/-
100kHz
Spectral Inversion Normal or Inverted
Return Loss min 18dB (typical 20 dB)
Receiver Signal Level Monitor +/-
6dB (typical)
FEC Mode VersaFEC
CCM Only
Decapsulation
Streamline
Symbol Rate Range
16Ksps to 4.5 Msps in CCM Mode
Spectral Mask 20%, 25% or 35%.
Data Rate 6Kbps to 15.35 Mbps and corresponds to symbol rate ranges in CCM Mode
Modulation and Code Rate Modulation
Code Rate
Min (Kbps) Max. (Kbps)
BPSK
0.488
16.0 2190.0
QPSK
0.533
18.0 4800.0
QPSK
0.631
21.0 5670.0
QPSK
0.706
23.0 6340.0
QPSK
0.803
26.0 7220.0
8-QAM
0.642
31.0 8670.0
8-QAM
0.711
35.0 9600.0
8-QAM
0.780
38.0 10530.0
16-QAM
0.731
47.0 13160.0
16-QAM
0.829
54.0 14910.0
16-QAM
0.853
55.0 15350.0
Descrambling V.35 or OFF
(FUTURE) I&Q Constellation
Via Web Server (HTTP)
Interface
Monitor Functions
Eb/No Frequency Offset
Corrected BER
Rx signal level
LNB current and voltage
Data and Management Interface 10/100 BaseT Fast Ethernet RJ-45
port
Terrestrial Traffic Interface 10/100/1000 BaseT Gigabit Ethernet (<360
Mbps) RJ-45 port
Command Line Interface (CLI) EI
A
-232
via DB-9
REMOTE port