Product specifications

CDD-880 Multi Receiver Router Revision 0
Preface MN-CDD880
xi
For 48 Volt DC standard router operation, use 3.15A fuses. These fuses are contained
within individual screw-in receptacles on the CDD-880 rear panel, below the terminal
blocks.
Low Voltage Directive (LVD)
The following information is applicable for the European Low Voltage Directive (2006/95/EC):
Symbol Description
<HAR>
Type of power cord required for use in the European
Community.
!
CAUTION: Double-pole/Neutral Fusing
ACHTUNG: Zweipolige bzw. Neutralleiter-Sicherung
International Symbols
Symbol Definition Symbol Definition
Alternating
Current
Protective
Earth
Fuse
Chassis
Ground
IMPORTANT
For additional symbols, refer to Cautions and Warnings listed earlier in this
Preface.
Installation
The installation and connection to the line supply must be made in compliance to local or national
wiring codes and regulations.
The CDD-880 is designed for connection to a power system that has separate ground, line and
neutral conductors. The equipment is not designed for connection to power system that has no
direct connection to ground.
The CDD-880 is shipped with a line inlet cable suitable for use in the country of operation. If it is
necessary to replace this cable, ensure the replacement has an equivalent specification. Examples
of acceptable ratings for the cable include HAR, BASEC and HOXXX-X. Examples of
acceptable connector ratings include VDE, NF-USE, UL, CSA, OVE, CEBEC, NEMKO,
DEMKO, BS1636A, BSI, SETI, IMQ, KEMA-KEUR and SEV.
Environmental
The CDD-880 must not be operated in an environment where the unit is exposed to extremes of
temperature outside the ambient range 0° to 50°C (32° to 122°F); precipitation, condensation, or
humid atmospheres above 95% relative humidity; altitudes (unpressurized) greater than 2000
meters; excessive dust or vibration; flammable gases; or corrosive or explosive atmospheres.