Anritsu’s MS2712E and MS2713E Spectrum Master spectrum analyzers provide users with high-performance for
field environments and for applications requiring mobility. There is no other spectrum analyzer in this class that can
deliver the same performance.
The combination of its performance and compact design makes it ideal for a broad range of activities, including
spectrum monitoring, interference analysis, field strength measurements, transmitter spectrum analysis,
electromagnetic field strength, signal strength mapping, and overall field analysis of cellular 2G/3G/4G,
land mobile radio, Wi-Fi, and broadcast signals.
Dynamic Range Performance
Low Level Performance
Limit Envelope
Comprehensive Marker Menu
High Performance
The dynamic range is better than 102 dB in 1 Hz, enabling measurement
of very small signals in the presence of much larger signals. The picture
demonstrates the dynamic range in the Spectrum Master
Displayed Average Noise Level
Spectrum Master delivers impressive and best-in-class DANL performance.
With the built-in pre-amp, better than 102 dBm DANL can typically be
realized in 1 Hz RBW. This low-level performance capability is essential when
looking for low-level interference signals.
GPS-Assisted Frequency Accuracy
With GPS Option 0031 the frequency accuracy is < 50 ppb. This additional
accuracy is important when characterizing 3GPP signals using counted
frequency markers. Also all measurements can be GPS tagged for exporting
to maps.
Simple but Powerful for Field Use
Convenience is a must in the field. This is why the Spectrum Master is
equipped with features that will enhance productivity in the field.
The Spectrum Master is equipped with limit lines for all user levels.
You can create single limit lines and segmented limit lines in one step using
the one-button limit envelope feature.
The Spectrum Master automatically sets the fastest sweep possible while
still ensuring accurate measurements. This allows users to rely on the
instrument to optimize accuracy and consistency.
Auto Attenuation ties the input attenuation to the reference level eliminating
the need for the user to determine how much attenuation is needed.
Six regular and six delta markers can be displayed with a marker table that
can be turned on as needed. The capability to measure noise level in terms
of dBm/Hz or dBµV/Hz is a standard feature of the Spectrum Master.
Best Performance in its Class