Change the mode to Static, and input the IP address, Netmask, Gateway and DNS information for your network.
Then click “Apply IP Settings”.
Please note: If you need to access Toolbox via Device Manager after this, you’ll need to click “Scan for Devices”
and log in again. Alternatively, you can open a browser to the new IP address (http://<new-ip-address>/cfg)
and log in that way.
The Primary Network page is also where you can adjust the port for web and xml services. Select Port under
Network (at the bottom of the screen) and enter the port number you would like to use. Be sure to press Save
once you’ve finished making your changes.
There are some additional “System” settings in the Toolbox Network section that can also be adjusted. They
are:
• Unit Name: By default, the unit name is “EarShot” folowed by the MAC address of the Primary Etehernet
port. We encourage users to give their units unique names to make them easier to identify on Device
Manager.
• Remote Diagnostics: This option (which, by default, is Off) allows Comrex Tech Support to use the ssh
protocol to diagnose problems. Only Comrex holds the encryption key for this port. It is not shared with
users for security reasons, and we recommend that it be left off unless you need to activate it to allow
Comrex Tech Support to access your unit remotely.
• System Clock: These settings control the EarShot IFB’s internal clock and how it synchronizes with the
network. Most users leave these settings at their default values, which is perfectly fine.
With each of these options, make sure to press Save once you’ve finished making your changes.