Safety Features
1. Low Battery Detection
When low battery condition occurs, the transmitter will turn off the fireplace.
A) Battery voltage is checked every one minute. When the battery voltage is low, the
LCD displays a low battery icon which will exist in all modes.
B) The transmitter will not operate with low battery voltage. Change the batteries before the
batteries become too weak for normal operations.
2. Power On Initialization
After the power-on initialization, the transmitter sends a signal to turn off the fireplace.
3. Thermal Shutdown
When the ambient temperature is more than 99°F, the transmitter will turn off the fireplace.
A) The LCD will display "HI".
B) The Transmitter will not function until the room temperature has dropped below 99 degree
Fahrenheit.
4. Low Temperature Condition
When the ambient temperature is less than 40 degrees Fahrenheit, the LCD will display
“LO”, and NO SIGNAL will be sent to turn on the appliance.
All functions still remain the same for both Manual Mode and Thermostat Mode
5. Child-proof Protection
The child-proof icon will be shown when the child-proof mode is activated by pressing the
ON button and the OFF button at the same time for three seconds.
A) Enter childproof mode by pressing and holding both the ON button and the OFF
button simultaneously for 3 seconds. The Childproof indicator will be shown on the LCD.
B) Deactivate childproof mode by pressing and holding the ON button and the OFF button
simultaneously for 3 seconds again. The Childproof indicator disappears on the LCD.
C) The transmitter can not be operated in childproof mode.
TROUBLESHOOTING
Symptom Causes Action
1. Battery icon on
LCD on transmitter.
2. LCD display is
blank
3. LCD display shows
“funny” display
1. Low Battery 1. Replace batteries. Change
batteries every 6 months.
2. Check battery installation or
replace batteries.
3. Reset the transmitter (see
Resetting the transmitter
section).
4. Appliance does not
come on.
2. The transmitter did not match with the receiver. 1. Make sure the transmitter has
learned to the receiver.
3. Transmitter measures temperature exceeding
99 degrees Fahrenheit and shows “HI” on LCD
1. Move transmitter to a cooler
place and wait until temperature
drops below 99 degree.