User's Manual

MHSC Touch Screen Full Function Signature Command Operating Instructions
Touch Screen Full Function Signature Command Operating Instructions
Page: 6
3. Press the THERMO button again to confirm the Set Temperature. The transmitter will send out an
On signal or an Off signal depending on the relationship between the Set temperature and the Room
temperature.
4. The flashing stops and the ON/up and OFF/down buttons become flame height controller again. The
flame height will then stay as set up by the ON/up and OFF/down buttons.
5. To exit Thermostat Mode, push and hold the THERMO buttons for 3 seconds.
Smart Mode Option for Thermostat Mode
Press and hold the THERMO button and the ON/UP button together for 3
seconds to toggle between Smart Mode and the regular Thermostat mode. The
icon “Smart Mode” will appear under the Set Temperature. The transmitter
will automatically adjust the flame height according to the difference between
the Set temperature and the Room temperature.
1. When T
SET
- T
ROOM
>= 3°F, flame height will be on High;
2. When T
SET
- T
ROOM
= 2°F, flame height will be on Medium;
3. When T
SET
- T
ROOM
= 1°F, flame height will be on Low;
4. When T
SET
= T
ROOM
, flame height doesn’t change;
5. When T
ROOM
> T
SET
, the fireplace will be shut off;
6. When T
SET
- T
ROOM
= 1°F again, flame height will be on Low;
7. The fan speed follows the flame height, if the fan is turned on.
Bower Speed Control
1. Press the FAN button to enter the blower speed control mode. The fan icon will start flashing.
2. Press the ON/up and OFF/down buttons to increase/decrease the blower speed.
3. Press the fan button again to confirm the speed setting. If the fireplace is on, the blower speed will
take effect right away; if the fireplace is off, the receiver will remember this setting and the blower is
still off (see blower On Delay and Off Delay in the next section).
4. After the signal is sent, the O N/up and OFF/down buttons become flame height controller again.
5. When the fan button is flashing, slide up and down on the arrow buttons will turn the blower speed to
High or Off derictly without pressing the fan button again to confirm.
Blower On Delay Time and Off Delay Time Setup
1. Hold the FAN button for 3 seconds until two numbers show up on the
LCD screen. The left number is blower On Delay Time and the right
number is blower Off Delay Time.
2. When the first number is flashing, use the ON/up button to set the desired
On Delay Time from 0 to 15 min.
3. Press the OFF/down button to jump to the Off Delay Time setup.
4. When the second number is flashing, use the ON/up button again to set the
desired Off Delay Time from 0 to 15 min.
5. Press the OFF/down button again to finish the setup and the new settings
will be transmitted to the receiver.
6. The default settings are 5 minutes for the On Delay Time and 8 minutes
for the Off Delay Time, as shown in the figure.