User's Manual
US Smart Outlet Purchase Spec September 21, 2012
Doc: D10025-002 Tendril Confidential Page 2
2 PRODUCT DESCRIPTION
2.1 Features
1) Smart Energy (SEP 1.1) certified via NTS or similar test house
a) AES 128 bit encryption across the HAN
b) Multiple ESI Support
c) Cluster Binding
d) ECC capability with Production Certificates
2) Switches 120V, 15A UL rated device on or off via SEP DR Clusters and Tendril custom control
commands. Device uses a latching SP relay that opens the hot side..
3) Application Bootloader OTA upgrade capability of radio FW.
4) Current, Voltage, and power measurement of attached loads, made available via the SEP Simple
Metering Cluster
a) ID = Instantaneous Demand = Power (V*I*PF)
b) CSD = Current Summation Delivered = Energy (kWh)
c) Voltage = Special Tendril Cluster
d) Current = Special Tendril Cluster
5) Certifications
a) UL 916 (Load Management Equipment)
b) Canadian UL Listed to Canadian Safety Standards (CAN/CSA 22.2)
c) FCC 15-B approval (US)
d) FCC ID and IC numbers on labels
e) Other International Certifications planned for future versions
1) Consumer safe, durable plastic housing for indoor use
2) Push Button for:
a) Opt out of DR events or other OFF condition
b) Scanning for networks for non-ECC HANs
3) Colored LEDs indicate status
2.2 Electronic Hardware Description
PCBs contains:
• ZigBee Radio Module containing:
o EM357 Radio SoC
o 100mW RF Power Amp operating at 2.4GHz
o 1MB external serial flash EEPROM
• 5V and 3.3V regulation
• Bi-color LED
• Switch for button
• Internal UART and test port connections sufficient to access the processor for programming at
initial manufacture, and validate PCBA functionality
• 150VAC / 16A minimum rated latching relay with 5V coil
• Current and voltage monitoring circuitry for the connected load
Further power and radio specifications are listed in the Performance Section below.