User's Manual
US Smart Outlet Purchase Spec September 21, 2012
Doc: D10025-002 Tendril Confidential Page 11
4.8.4 Non-Operational Vibration
The product shall pass a test conducted as described in ICE 60068-2-6 REV 1987 based on the following
conditions:
1. The device shall not be operating and shall be without packaging.
2. The device shall be rigidly mounted to a test fixture and at reference point for the control
accelerometer that shall be attached to the test fixture.
3. The test shall be run over a frequency range of 30 to 350 Hz with a sweep time of one octave per
minute at 5 m/s^2 (0.5 g) along each of three mutually perpendicular axes.
4. The sweep duration shall be 30 minutes also each axis.
5. Post test an accuracy performance check shall be performed to verify function.
Specification Value
Frequency Range
30 - 350 Hz, sweep of one octave/minute
Acceleration Level
0.5 G (5 m/s2) along each axis
Application
1.5 hour total test time. 30 minutes along each axis
4.8.5 Operational Random Vibration
The product shall pass a test conducted as described below based on the following conditions:
1. The device shall be operating and shall be without packaging
2. The device shall be rigidly mounted to a test fixture and at a reference point for the control
accelerometer that shall be attached to the test fixture
3. The test shall be run over a frequency range of vibration as described below.
4. Concurrent with vibration and post test, an accuracy of performance check shall be performed to
verify function.
Random Vibration
Specification Value
Frequency Range
1-400 Hz
Acceleration Level
1.06 G
rms
Application
3 sides - 20 minutes per side
PSD Spectrum
Frequency PSD (g2/Hz)
1 Hz
0.0003
3 Hz
0.0055
12-100 Hz
0.01
400 Hz
0.000003