User's Manual
50D0096 Rev 0 Aug 2005 Page 8 of 10 Ambient Technologies
A Division Of
Monessen Hearth Systems
Transmitter Thermal Shutdown:
1. If transmitter measures a room temperature exceeding 99 degrees Fahrenheit, the
LCD will display "HI" and the transmitter will turn off the appliance.
2. Transmitter will not function until the room temperature has dropped below 99
degree Fahrenheit. If transmitter measures a room temperature less than 40
degrees Fahrenheit, the LCD will display “LO” and NO SIGNAL will be sent
to turn on the appliance.
Receiver:
Slide Switch:
1. ON position: the main burner will ignite and blower will come on when Blower on Delay Time is reached
and fan speed has been enabled; otherwise just burner will ignite until the slide switch is placed in the OFF
or RS position to turn burner off.
2. RS position: the system will only operate if the remote receiver receives a signal from the transmitter.
3. OFF position, the system is off. If fan speed has been enabled blower will continure to operate until Off
Delay Time expires. The slide switch should be placed in the OFF position if you will be away for an
extended period of time. If the remote receiver is mounted out of children’s reach, the OFF position also
functions as a safety device by both turning the system off and rendering the receiver inoperable.
Optional Auto Shutdown:
1. The receiver comes preset from the factory with a 6 hour shutdown from its last ON operation. This is
done to prevent the appliance from continuing to run if unattended.
2. You may disable this feature if you wish. To disable, change the receiver privacy (DIP) switch #1 ONLY
to the OFF position. Make sure the receiver privacy (DIP) switches are set the same. Follow the
instructions on how to set the privacy (DIP) switch setting.
3. By disabling this feature, your appliance may continue to run unattended.
Optional Wall Cover Plate:
1. Receiver snaps into wall cover plate. The wall plate is mounted by using 2 screws provided.
TESTING YOUR NEW REMOTE CONTROL SYSTEM
1. Light your gas appliance following the appliance lighting instructions that came with the appliance.
Confirm that the pilot light is on; it must be in operation for the remote control to operate the main gas
valve and blower. Appliance control knob must be in the ON position, and appliance ON/OFF switch must
be in OFF position.
2. Slide the 3 position button on the remote receiver to the ON position and the main gas flame should ignite.
3. Slide the button to OFF and the main gas flame should extinguish, but the pilot light will remain on.
4. Slide the button to RS (the center position), then press the ON button on transmitter to turn the system ON.
The main gas flame should ignite and blower should come on after the On Delay Time is reached and fan
speed you desire is selected.
5. Press the OFF button on transmitter to turn the system to OFF. The flame should extinguish (the pilot light
will remain on) and blower should be off after the Off Delay Time you set.