User's Manual

50D0096 Rev 0 Aug 2005 Page 7 of 10 Ambient Technologies
A Division Of
Monessen Hearth Systems
3-Speed Bower Control:
1. Press FAN button once to enter blower speed setup mode at low speed
initially and one of the three blade icon will display darken on LCD.
2. Continue to press FAN button to set up the blower speed you desire.
3. If there is no input within 3 seconds, the new setting will be transmitted to
receiver. If fireplace is on, the blower speed will take effect right away; if
fireplace is off, the receiver will remember this setting and blower is still off.
4. If you continue to press FAN button while fire is on or off the FAN icon will
disappear and turn the blower off.
Blower On Delay Time and Off Delay Time Setting:
1. Hold FAN button for 5 second and two numbers will show up in LCD screen.
The upper one is On Delay Time and the bottom is Off Delay Time.
2. Use the ON /
Δ button to set the desired On Delay Time from 0 to 15 min.
3. Use the OFF /
button to set the desired Off Delay Time from 0 to 15 min.
4. If there is no input within 3 seconds, the new setting will be transmitted to
receiver.
5. The default settings for both transmitter and receiver are 5 minutes for On
Delay Time and 8 minutes for Off Delay Time, as shown in this picture.
NOTE The most efficient setting for your fireplace blower is when blower comes
on and off, it is blowing warm air only not hot air. Giving the fireplace as
much time to discharge as much warm air as possible before turning off.
Low-battery detection:
1. Battery voltage is checked once a minute. When the battery voltage drops to a
certain level, the low-battery icon will display on LCD, and the transmitter
will turn off the appliance. The transmitter will not function anymore until
fresh batteries are installed.
2. When the batteries are low, the LCD displays a low battery indicator. The low
battery indicator will be displayed in any mode.
3. The transmitter will not operate with low batteries. Change the batteries before
the batteries are too weak for normal operation. TURN THE UNIT OFF
BEFORE REPLACING BATTERIES.
Child-proof protection:
1. Press and hold the ON and OFF buttons simultaneously for 3 seconds to enter
childproof mode as shown in this picture.
2. The transmitter will not send a signal again until childproof mode is deactivated
by pressing the ON and OFF buttons simultaneously for 3 seconds to exit
childproof mode and the Childproof indicator disappears from LCD.