User's Manual

50D0096 Rev 0 Aug 2005 Page 6 of 10 Ambient Technologies
A Division Of
Monessen Hearth Systems
OPERATIONS
Transmitter:
General:
The RCSTEB Remote Control has two (2) operating modes: Manual and
Thermostatic. The control system can be set to temperature ranges between 45°F and
90°F. The blower speed can be adjusted in either the manual and thermostatic mode.
The transmitter will operate the remote receiver from 1foot to a maximum of 30 feet.
The distance is reduced when batteries are low or when the receiver is inside a metal
enclosure.
Initial start up:
1. After initial power up or when RESET button is pressed, the transmitter is reset.
The reset button is located behind the battery door of transmitter.
2. During system reset, all features of the LCD will be visible. After one second,
the LCD will be initialized. A typical reset display is shown above. Note that
the temperature scale is degree F.
3. Press On button to select between °C and °F display. It will exit setting mode
automatically after 10 seconds if no key is pressed. The transmitter will send
an Off signal after reset.
4. After reset, the transmitter is operating in manual mode. The room temperature
is shown as above.
Manual Mode:
1. Press the ON button once to turn on the appliance. Press the OFF button to
turn it off.
Thermostatic mode:
1. Press the AUTO button to enter the thermostatic mode.
2. In thermostatic mode, press the ON /
Δ button or OFF / button to set the
desired set temperature.
3. Once the setting is completed, the transmitter will automatically turn on the
fireplace when the room temperature is below the set temperature and turn off
the appliance when the room temperature is above the set temperature within 1
degree.
4. There will be a slight delay in the response of the unit (on/off) to a temperature.
Room temperature is monitored every 3 minutes.
5. Press the Auto button to exit the thermostatic mode (Return to Manual Mode).
The transmitter will be in the manual on/off mode and receiver / transmitter will
maintain the previous settings of Fan speed & blower Delay on & Delay off time.