This system comes with an 22 inch wire assembly labled “MV VALVE”. Insert the white terminal into the back of
the receiver. The terminal wire block can only be installed one way and do not force the terminal plug into the
receiver.
Connect the wiring terminal two (2) ¼” female spade terminals to the appliance valve. Refer to the appropriate
Homeowner’s Manual for proper wiring connections to the appliance. Your appliance may have other options to
connect wiring from receiver. For applications longer than 22 inches, use 18 gauge wire, 105ºC rated, with no
splices. Connect to the two (2) 1/4“ female spade wiring terminals and wire can be no longer than 20 feet.
WARNING
Speed control module and thermal sensor must be removed before installing receiver and
applying the AC power. Failure to do so may cause the part damage and void the warranty.
Without removing the control module and thermal sensor, they and RCSTEB both will try to
operate the blower at the same and may cause unexpected blower operation or damage.
Before connecting the blower with the receiver, always DISCONNECT SPEED CONTROL MODULE AND
THERMAL SENSOR from your fireplace if they exist as displayed in following diagram:
120VAC
BLOWER
WHITE
GREEN
120VAC
BLOWER PLUG
BLACK
MV VALVE
TP
TP/TH
THERMAL
SENSOR
BLACK
BLACK
120VAC
FOR RECEIVER
MALE FEMALE
MALE
FEMALE
WHITE
BLACK
120VAC SPEED
CONTROL
MALE
FEMALE
BLACK
BLACK
BLACK
RECEIVER
Connect the two 30” long 18AWG wires labled “110VAC FAN ONLY” between receiver and blower as shown in
the follwing diagram as well.