5.1.4 Pulses define:
5.1.4.1 Wide pulse is defined as bit ‘0’ and narrow pulse as bit ‘1’.
5.1.4.2 Wide pulse width is 640us and narrow width as 320us, +/-10%.
5.1.4.3 Duration between two pulses ( pulse rising edge to previous falling edge): for next wide
pulse: 640us and for next narrow pulse: 320us.
5.1.4.4 Duration between each16 bit command: 12ms +/-10%
5.1.4.5 Total Number of Command: 2.6s, +/-10%