Fireplace new platform product specification
Copyright © 2014 Computime Limited. All rights reserved. Rev. 1.2
Page 7
3.2. Receiver functional specification:
3.2.1. ID setting: The receiver ID must match with transmitter ID. The 4 position DIP switch will
applied for receiver board.
3.2.2 Slide Switch: The slide switch should be used to perform the manual control or specific
functions as defined for each individual receiver.
The fireplace operation should start at remote position. When slide switch starts from ON or OFF
position after new battery installed or reset, no operation should perform and system should be in
shutdown states. When fireplace starts at remote position, the fireplace will be in flame off state.
The fireplace starts the fire control if it receives the flame on command from transmitter.
When slide switch moves from RS to ON position, the fireplace should be turned on at its highest
flame height. Six hour shutdown operation should not be performed.
When slide switch moves from ON to RS position, the fireplace should resume the previous state
operated at RS position.
When slide switch moves from RS to OFF position, the fireplace should be shut off. Six hour
shutdown operation should not be performed.
When slide switch moves from OFF to RS position, the fireplace should resume the previous state
operated at RS position.
3.2.3 During power up the receiver, the LED will flash 3 times, and the duration is 500ms on every
flash. Then, LED will turn on 5 seconds. After that, LED will turn off.
3.2.4 Connector: A 2pins connectors should be used to provide all external connection for ON/OFF
control.
3.2.5 RF module and Antenna: A 350MHz RF module is used for communication with Remote. It
must meet the range of more than 30 feet when the receiver assembly on fireplace.