8.2 Functional design
The functional design is left open to best fit the production requirements and the aesthetic design
9 SOFTWARE REQUIREMENTS
NA
10 ENVIRONMENTAL REQUIREMENTS
10.1 Temperatures
10.1.1 Storage temperature
10.1.1.1 The storage temperature for all devices shall be -20 - +85°C
10.1.2 Operating temperature
10.1.2.1 The operating temperature for all devices shall be 0 - +45°C
10.2 Humidity
10.2.1 Storage humidity
10.2.1.1 The storage humidity for all devices shall be 10-98%RH non-condensing
10.2.2 Operating humidity
10.2.2.1 The operating humidity for all devices shall be 15-95%RH non-condensing
10.3 Protection
A general test shall be made with each device to find which components that is sensitive to
condensation. Those areas shall then be protected with conformal coating.